YCDZ 3X25+2X10 HOIST & CRANE GJJ CABLE
Cable H07RN-F 3G1.5
450/750V VDE approved copper conductor EPR insulated CPE sheathed H07RN-F cable
Flexible rubber cables H07RN-F
Flexible rubber cable H07RN-F
Flexible copper rubber cable H07RN-F
Copper cable H07RN-F
Rubber insulated cable H07RN-F
Rubber cable HO7RNF
High quality construction hoist spare parts
High quality GJJ, BAODA material hoist spare parts
Normal Cross Sectional Area of Conductor (mm2 ) | Normal Diameter of Strand (mm) | Normal Thickness of Insulation (mm) | Normal Thickness of Jacket (mm) | Over Diameter of Cable (mm) | Max Conductor Resistance at 20ºC ( ≤Ω/km ) |
2×0.75 | 0.20 | 0.6 | 0.8 | 4.0×6.4 | 4.4×7.2 |
2×1 | 0.20 | 0.6 | 0.9 | 4.3×6.8 | 4.7×7.6 |
2×1.5 | 0.25 | 0.8 | 1.0 | 5.2×8.4 | 5.7×9.4 |
2×2.5 | 0.25 | 0.9 | 1.1 | 6.0×9.8 | 6.5×10.8 |
2×4 | 0.30 | 1.0 | 1.2 | 7.0×11.6 | 7.6×12.8 |
2×6 | 0.30 | 1.0 | 1.3 | 7.8×13.0 | 8.4×14.2 |
3×0.75 | 0.20 | 0.6 | 0.9 | 4.2×9.0 | 4.6×9.8 |
3×1 | 0.20 | 0.6 | 0.9 | 4.3×9.3 | 4.8×10.3 |
3×1.5 | 0.25 | 0.8 | 1.0 | 5.2×11.5 | 5.8×12.7 |
3×2.5 | 0.25 | 0.9 | 1.1 | 6.0×13.6 | 6.7×15.0 |
3×4 | 0.30 | 1.0 | 1.2 | 7.0×16.0 | 7.8×17.6 |
3×6 | 0.30 | 1.0 | 1.3 | 7.8×18.0 | 8.8×20.0 |
4×0.75 | 0.20 | 0.6 | 0.9 | 4.2×11.4 | 4.7×12.4 |
All kinds of hoist spare parts , GJJ,BAODA,ZOOMLION,TIGER,
Driving device with 2-motors / 3-motors;
motor: 11kw, 14.5kw,18kw;
motor spare parts: braking system; brake sheet, motor adjustor, electromagnet,motor fan.
safety device: 30KN,40KN,50KN,60KN;
gearbox: 16:1,14:1,12:1;10:1;
coupling with rubber;
master rollers for 76 tube and 89 tube;
gear rack M8 40x60x1508mm;
gear pinion: M8,15teeth;
limit switch;
gate rollers;
counter rollers;
transformer;
Overload protect system;
cable: 3x16+2x6, 3x16+2x10
All kinds of hoist spare parts
Driving device with 2-motors / 3-motors;
motor: 11kw, 14.5kw,18kw;
motor spare parts: braking system; brake sheet, motor adjustor, electromagnet,motor fan.
safety device: 30KN,40KN,50KN,60KN;
gearbox: 16:1,14:1,12:1;10:1;
Our products are mainly exported to Brazil, Vietnam,Turkey, Russia and Malaysia. We can meet our customers' needs well. We can produce products according to customers' special requirements.We sincerely hope to cooperate with you in the future.
Characteristics of Cable
1.Max Long-time operating temperature of PVC insulated cable is 70°C,XLPE 90°C
2.Installing temperature of cable should not be less than 0°C
3.Max short-circuit temperature is:PVC not exceed 160°C,XLPE 250°C,Not more than5 Sec.
4.Permitting bending radius cable: Not less than 10 D times (D:external diameter of cable)
5.Perfect chemical stability, resistant against acids, alkali, grease and organic solvents, and flamer retardant.
Application:
It is widely used at the transformer circuit which rated voltage is 6000V or under.